General Specifications
(Through applying 500VDC between impeller hub center and lead wire (+) )
(For models without PWM control function,there is no speed control wiring.)
Item No. | Operating Voltage |
Maximum Air Flow |
Maximum Air Pressure |
Rotational Speed |
Rate Current |
Input Power |
Noise | ||
(V) | (CMM) | (CFM) | (mmAq) | (inchAq) | (RPM) | (A) | (W) | dB(A) | |
CHA10012BL-O25(b) | 12 | 0.82 | 28.82 | 7.84 | 0.31 | 2800 | 0.20 | 2.40 | 40.65 |
CHA10012BM-O25(b) | 12 | 0.89 | 31.48 | 9.58 | 0.38 | 3100 | 0.30 | 3.60 | 42.86 |
CHA10012BH-O25(b) | 12 | 1.13 | 39.76 | 15.70 | 0.62 | 4300 | 0.45 | 5.40 | 49.97 |
CHA10012BX-O25(b) | 12 | 1.29 | 45.65 | 21.14 | 0.83 | 4600 | 0.65 | 7.80 | 51.43 |
CHA10024BL-O25(b) | 24 | 0.82 | 28.82 | 7.84 | 0.31 | 2800 | 0.15 | 3.60 | 40.65 |
CHA10024BM-O25(b) | 24 | 0.89 | 31.48 | 9.58 | 0.38 | 3100 | 0.20 | 4.80 | 42.86 |
CHA10024BH-O25(b) | 24 | 1.13 | 39.76 | 15.70 | 0.62 | 4300 | 0.35 | 8.40 | 49.97 |
CHA10024BX-O25(b) | 24 | 1.29 | 45.65 | 21.14 | 0.83 | 4600 | 0.50 | 12.00 | 51.43 |