General Specifications
(Through applying 500VDC between impeller hub center and lead wire (+) )
(For models without PWM control function,there is no speed control wiring.)
Item No. | Operating Voltage |
Maximum Air Flow |
Maximum Air Pressure |
Rotational Speed |
Rate Current |
Input Power |
Noise | ||
(V) | (CMM) | (CFM) | (mmAq) | (inchAq) | (RPM) | (A) | (W) | dB(A) | |
CHA4012BH-A28(b) | 12.00 | 0.33 | 11.54 | 9.01 | 0.35 | 9000 | 0.30 | 3.60 | 36.65 |
CHA4012BX-A28(b) | 12.00 | 0.50 | 17.55 | 17.32 | 0.68 | 13500 | 0.50 | 6.00 | 45.40 |
CHA4024BL-A28(b) | 24.00 | 0.85 | 29.90 | 50.27 | 1.98 | 23000 | 1.50 | 36.00 | 56.97 |